Epid qc phantom and epidsoft software epid qc phantom has been designed to check and monitor the image quality of epids used in highenergy photon beams. Dosimetry and qa solutions for halcyon product overview. When a calibration image is processed, the information is saved and will be used for all subsequent clinical images until a new. Improved compare functions with different reference points for gamma index analysis and advanced 3 d gamma analysis.
It provides the basic image quality uniformity etc. The dosimetry check software was used to evaluate patientspecific qa on the two imrt techniques step and shoot, as well as smart arc with measurements based on epid set to 110 cm sdd. Pretreatment dosimetry by means of 2dimensional 2d dosimeters or directly by the electronic portal imaging devices epids 1,2 is commonly used to assess the accuracy of computed treatment planning system tps and dose distributions of intensitymodulated radiotherapy imrt beams, but the method is time consuming and the dose differences. The muepid software has been developed using matlab version 9. The versatile phantom provides a wide range of test elements to check all relevant quality parameters of mv imagers with a single beam in one image. Overlaying this calibration with an existing absolute calibration can give you a measurement of the overall accuracy. The dose response measured under different acquisition settings and different linacepid combinations matched closely. Adaptivo displays relevant information without overloading the user. Either route will require substantial commissioning. Step wedge and uniform irradiation are the two options currently implemented for the calibration of the system. Epid dosimetry configuration and pretreatment imrt. Cureus commissioning and evaluation of an electronic. Epid calibration method for transit invivo dosimetry. Dose calibration of epids for segmented imrt dosimetry.
Dosimetry check uses the electronic portal imaging device epid or detector array to capture images measuring the xray intensity applied to the patient. It is possible to utilize epiqa for a verification of static as well as intensity modulated fields, including rapidarc fields. The pdp software is commissioned for portal dosimetry in tps eclipse version11, varian, palo alto, ca, united states, at hospital of ain shams university, cairo. Adaptivo satisfies the requirements for both pretreatment qa and invivo or transit dosimetry. When a calibration image is processed, the information is saved and will be used for all subsequent clinical images until a new calibration image is received and processed. Patient specific pretreatment qa verification using an. Epiqa tm is a program that allows to convert a dosimetric image acquired by an epid into a dose map and to compare the dose map with a reference dose distribution. Epigray, epidbased transit dosimetry software receives a. The software recently received 510k clearance from the u. See how dolphin setup is completed in one minute by the hospital staff at the klinikum bayreuth, germany. Epigray was commissioned based on the companys instructions.
X 10 cm, y 10 cm monitor units 100 1cu was scaled to 100 mu at sid 100cm. The epid calibration method calculates portal dose values with an uncertainty of less than 3% 1 sd, the calibration of the mv conebeam ct scan into electron density values results in maximum differences of 2% in the dose distribution, and the 3d monte carlo based dose calculation evaluated for headandneck cancer patients showed. In addition to accurate 3d dose verification, in vivo epid based dosimetry will also detect major errors in the dose received by individual patients. Clinical imrt epid dosimetry implemented with the different pixeltodose calibration methods indicated that calibration at 20 mu provides equivalent results to implementing a ghosting. The investment in getting epid dosimetry into clinical use for ivd cannot be neglected in terms of either developing or purchasing software to facilitate ivd using the epid output. Patient specific pretreatment qa verification using an epid. The graphical user interface gui has two principle functions which are a epid image calibration and b imrt qa. Dosimetry calibration the dosimetric calibration was performed at the same sid used for the dark field and flood field calibration. The first step was calibration of the asi epid mounted on three linear accelerators clianc23exs, varian.
Many papers have reported on the use of epid dosimetry for patient. The epid name can be different see the next example. Portal dosimetry portal vision asi imager panel of varian clinac is used, with a pixel dimension and spatial resolution of 1024. Initial calibration of an inhouse software tool includes characterization of epid dosimetry parameters by importing dicom images of varying delivered mus to determine linear mapping factors in order to convert image pixel values to variandefined calibrated units cu. Once the dosimetry mode on the varian truebeam was calibrated, the data acquisition required for the software commissioning took about three hours of measurements per beam energy and per machine. The epid shows promise as a device for verification of imrt, the major. This technique can be used to eliminate field size dependencies in film, epid and cr images. This reconstructed dose is then compared to the intended dose from the planning system. Software is required to analyze the results of epid measurements and produce predicted results to allow comparison.
Radiation dosimetry in the fields of health physics and radiation protection is the measurement, calculation and assessment of the ionizing radiation dose absorbed by an object, usually the human body. Select the gamma criteria values distance in cm and percent difference including the dose to compare to what the percent is of. Epid qc phantom has been designed to check and monitor the image quality of epids used in highenergy photon beams. Clinical imrt epid dosimetry implemented with the different pixeltodose calibration methods indicated that calibration at 20 mu provides equivalent results to implementing a ghosting correction. The mu epid software has been developed using matlab version 9.
Epid qc phantom epidsoft software ptw freiburg gmbh. To perform qa for imrt with portal dosimetry, one uses analytic software to correlate the response of an amorphous silicon asi epid to the dose delivered by applying positionspecific factors from a dose calibration table. The literature reports good digital image quality, shorter exposure time and dosimetric properties of asi epid 818. Founded in 2002, dosisoft develops cuttingedge software solutions in the field of advanced software for radiation oncology and nuclear medicine, with a strong expertise in dosimetry. Routine epid invivo dosimetry in a reference point for. This applies both internally, due to ingested or inhaled radioactive substances, or externally due to irradiation by sources of radiation. Cureus commissioning and evaluation of an electronic portal.
Establishing action levels for epidbased qa for imrt. We provide solutions in over 200 hospital centers in 38 countries. The analysis software follows the scaling, outputcorrection, and dose redistribution steps for these large epid calibration images outlined above, and then creates a pixelbypixel lookup table of pixel valuetodose calibration factors by referencing against the measured calibration absolute dose planes. The essentials of epidbased dosimetry are the accuracy of the imager calibration and the cal culation algorithm. Calculate the transmissions from epid images of a large field passing through a series of homogeneous, planar, plastic phantoms, with different physical thicknesses. Epid central signals, obtained at source to epid distances sed equal to 159cm or 150cm, were converted into dose at a reference point in the patient.
Dosimetry check operating manual, page 12 of 43 for details see the plan section of the dosimetry check reference manual. This work will contribute to a more consistent understanding and implementation of pixeltodose calibration methods for epid based imrt dosimetry. Leading provider of radiation calibration and qa equipment for dosimetry, brachytherapy, intensitymodulated and imageguided radiation therapy, and stereotactic. Dosimetry check dc operating manual math resolutions.
Imrt patient plan verification software for comparing dose distributions measured in an imrt verification phantom with dose distributions computed by a rtps. It can also be used with an ion chamber array to produce fast absolute dose calibration at. Learn more because this system is fully automated so that no physicist time is required for data acquisition and evaluation, daily patient treatment qa is feasible. For more information on ptw dosimetry and qa solutions, visit. This was performed using the truebeam imaging system calibration workflow. Adaptivo drastically reduces the amount of time required for pretreatment qa when compared to using a phantom. Independent verification of the dose delivered by complex radiotherapy can be performed by electronic portal imaging device epid dosimetry. The calibration of epid is done, where radiation beam is linked to calibration units cu. Radiation therapy innovative, industryleading dosimetry solutions for safer cancer patient treatments. The aim of this study is to evaluate the ability of transit dosimetry using commercial treatment planning system tps and an electronic portal imaging device epid with simple calibration method to verify the beam delivery based on detection of large errors in treatment room. Epiqa is a commercial software which we use for the independent verification of imrt treatments with the varian epid electronic portal imaging device. All evaluations on this page were performed with version 2. Epid detector design, the linac, and the image acquisition and processing methods implemented across different systems. Those images are then converted back to an inair fluence map from which the dose is calculated in 3d back on the patient ct.
Darkfield and floodfield calibration of all imrt scanning modes that shall be used for portal dosimetry, e. Identify the calibration relationship between transmission and physical thickness of plastic phantom. Dosisoft sa, french software leader specialized in radiotherapy and medical imaging, is pleased to announce that epigray, epidbased transit dosimetry solution, has received a medical device licence from health canada, on the 2nd of february, 2016 and is now available for sale on the canadian market. As a result of the calibration the predict ed and measured fl uency map can be expressed in calibrated units cu.
Epid based transit dosimetry to monitor interfraction. The epid response is graded to the extent that 1 cu is matched to 1 mu delivered. The epid response depending on the beam mode, treatment time and static square field size was measured. Webbased qa data management software trackit qa data management highlights integrated platform to automate and streamline data management in radiotherapy qa oneclick export of analyzed qa data from ptw devices. It also helps to easily determine which patients require replanning. The list of eight items would be repeated for a second and subsequent epids. Evaluation of a fast method of epidbased dosimetry for. Epid dosimetry ccdbased epid research started in 2000 point dosimetry clinically used from 2002 to 2006 2d dosimetry flatpanel dose calibration for asi epids started in 2005 pretreatment in clinical use from june 2006 present. Any inaccuracy in that proc ess could lead to inconsistency between the pre dicted and measured dose. The additional correction of the conversion factors reduced a systematic discrepancy between appa and lateral beams for single fields by 2%, which. Vivo dosimetry software electronic portal imaging device. Epids have also been used for dosimetry in radiation therapy mcdermott et al 2004, winkler et al 2005, van esch et al 2004, greer and popescu 2003, siebers et al 2004, kirkby and sloboda 2005. Subsequently, the epigray calibration and conversion factors were defined.
Iba dosimetry is the global market leader for independent integrated quality assurance solutions and services that maximize efficiency and minimize errors in radiation therapy, medical imaging, and calibration procedures. The algorithms and the software, used to perform the ivd checks, are described elsewhere fidanzio 2010, et al piermattei et al 2012. Epid dosimetry 2d and 3d verification methods van elmpt et al. Ebtx and flatbed scanner correction this advanced feature corrects for flatnessand uniformity variations in scanners, corrects for nonuniformities in ebt2 and ebt3 film to improve the films dosimetric accuracy, and provides you with the option to automaticallygenerate a calibration file. Epid based transit dosimetry to monitor interfraction variation in radiation therapy bawazeer, o 2018, epid based transit dosimetry to monitor interfraction variation in radiation therapy, doctor of philosophy phd, health and biomedical sciences, rmit university. The program will default to the plan dose at the average isocenter of all the fields. After the initial commissioning process, clinical experiments on phantom treatments were evaluated to assess the level of accuracy of the electronic portal imaging device epid based invivo dose verification. Results are analyzed in 3d using epid andor log file data, or in 2d through the transit dosimetry feature, with no additional time or effort required. This allows clinicians to spend more time on patients who need adjustments to their plans, while providing the justification necessary for billable replanning. The epid measurements were also found to depend on the input beam profile utilized for epid floodfield calibration. Succinct metrics and graphs communicate analysis and warnings, and user editable tolerances direct attention only when needed.
Rit patient qa imrt, planbased calibration, batch analysis. Afterwards, configuration of the calculation algorithm in tps was carried out. Then dosimetric characteristics of the epid were investigated. To calibrate the megavoltage mv dosimetry mode, diagonal beam profiles are imported as described in the varian user guide. Twenty four fields of intensity modulated radiotherapy imrt plans were selected from four lung cancer patients. See the epidos website for details and current releases.
The essentials of epid based dosimetry are the accuracy of the imager calibration and the cal culation algorithm. New elekta iviewdose software designed to provide an. Epid in vivo dosimetry in rapidarc technique request pdf. Epid based in vivo dosimetry provides clinically more useful information and is less time consuming than patientspecific pretreatment dose verification.
Radiation calibration, qa, and dosimetry equipment stand. Epidbased dosimetry, in combination with inroom imaging, is a fast and accurate tool for 3d in vivo verification of vmat delivery. First step was calibration of the asi epid mounted on three linear accelerators clianc23exs, varian. Pdf commissioning and evaluation of an electronic portal. Evaluation of dosimetry check software for imrt patient. This work will contribute to a more consistent understanding and implementation of pixeltodose calibration methods for epidbased imrt dosimetry. In vivo dosimetry in uk external beam radiotherapy. Pdf dose calibration of epids for segmented imrt dosimetry. Epidbased in vivo dosimetry provides clinically more useful information and is less time consuming than patientspecific pretreatment dose verification. Commissioning as electronic portal imaging device, epid.